ELECTRONIC POWER STARTER

Electronic power starter (EPS) is intended for switching ON/OFF of voltage in high-current circuits:

  • EPS-1 for single-phase loads;
  • EPS-2 for three-phase loads.  

It’s contactless and nonsparking starter, that increases reliability and durability and decreases fire danger, noises and radio-interference.

SPECIFICATIONS

Operation voltage 200…240 V
Max.load current EPS-1 25 A
Max. load current EPS-3 for each phase 40 A
Turn-on time 10 ms
Max. voltage of isolation, no more than 1000 V
Temperature regulation range 100…900C
Temperature setting accuracy ±50C
Weight 
EPS-1 0,5 kg
EPS-3 1,1 kg
Dimensions  
EPS-1 160x80x80 mm
EPS-3 195x100x100 mm

PHOTORELAY 

The photorelay is intended for automatic insertion and cutout of illuminators depends on lighting.

 

SPECIFICATION

AC supply voltage 220V
MAx. power commutation 100W
Dimensions 100x60x40mm

TIMER

The timer is made on basis of electromechanical clock. it is made on base of electromechanical clock and provides automatic switching off at given time.

SPECIFICATIONS 
AC Supply voltage 220V
Max. delay time 11 hours
Max.power commutation 1500W
Dimensions  110x90x70

LIGHT’S AUTO-CUTOUT

The light’s auto-cutout is intended for switching ON and auto-cutout of illuminators in rooms where  lighting is not necessary: entrances, holding allays and barns of apartments and offices.

The auto cutout is carried out after definitive time, which will be given on the customer’s request.

Using of auto cutout allows to decrease annual power consumption of one holding allay of the five-storey house on 2000 kW/h and increase life time of illuminators in 6 times.

Number of switches is unlimited.

SPECIFICATIONS

Supply voltage 190…250V
Max.power commutation 150W
Power consumption, no more than 1W
Max. delay time 5min
Weight 220g
Dimensions 120x85x70mm

NEON TRANSFORMER «SPEKS»

The neon transformer «SPEKS» is intended for neon lamp switching ON/OFF. 

Transformers “SPEKS” (flowable), which haven’t any analog in the world, provide smooth filling glow in tubes (effect of glow flow). 

Due to new constructive solutions the device differs from traditional transformers with subminiature weight, high reliability and efficiency up to 65 % energy.

The transformer has the integrated protection at blowout and short circuit in secondary circuit, at false disconnecting under the influences of capacitive current. In case of fivefold repetition of blowout and short circuit modes the transformer is disconnected automatically.

 

SPECIFICATIONS 

Primary current 180…240 V
Value of input current at maximum load 0,45 A
Output voltage 1500…10 000V
Secondary current 30 mA
Operation temperature range minus 400C…+400C
Overall dimensions 100x49x36 mm
Weight 0,28 kg
Length of high-voltage terminal 800 mm